Rear Door Heat Exchanger for AI & Data Centers
Core Technical Advantages
-
Door-Integrated, Zero Floor Space Design Mounts directly to the rear of standard server racks, requiring no additional floor space and simplifying deployment in new and retrofitted data centers.
-
Direct Hot Air Capture Captures server exhaust air at the rack rear, eliminating hot air recirculation and reducing the need for raised-floor air conditioning.
-
High-Capacity Heat Rejection Efficiently transfers waste heat from exhaust air to chilled water loops, supporting high-density AI and HPC workloads with minimal facility cooling overhead.
-
Flexible Deployment Compatible with both new liquid cooling data centers and retrofitted facilities with existing chilled water infrastructure, enabling phased liquid cooling adoption.
-
Low-Noise, Energy-Efficient Operation Reduces reliance on high-speed rack fans and raised-floor air conditioning, lowering overall data center PUE and noise levels.
Product Specifications
|
Attribute |
Specification |
|
Brand |
EXTRCOOL |
|
Model Series |
RDHX-Series Rear Door Heat Exchanger |
|
Cooling Type |
Air-to-Liquid Heat Rejection |
|
Product Category |
Rack-Mounted Rear Door Heat Exchanger |
|
Compatible Systems |
Standard 19-inch server racks, chilled water networks |
|
Place of Origin |
Guangdong, China |
Ideal Application Scenarios
- High-Density AI Data Centers: Supports 30–50kW rack loads for GB200/GB300 GPU clusters.
- HPC & Supercomputing Clusters: Eliminates hot spots in high-performance computing environments.
- Traditional Data Center Retrofit: Enables phased liquid cooling upgrades without major infrastructure changes.
- Colocation & Enterprise Data Centers: Reduces facility cooling loads and supports mixed-density rack deployments.
- Edge & Compact Data Centers: Ideal for space-constrained facilities with limited raised-floor cooling capacity.
Why Choose EXTRCOOL Rear Door Heat Exchanger?
The rear door heat exchanger offers a non-intrusive, space-efficient solution for increasing rack power density without major facility overhauls. EXTRCOOL’s RDHX combines direct hot air capture, high heat rejection efficiency, and flexible deployment to meet the evolving needs of AI and HPC workloads, ensuring stable, energy-efficient operation year-round.
Frequently Asked Questions
1.What is a Rear Door Heat Exchanger used for?
A Rear Door Heat Exchanger (RDHX) is a rack-mounted liquid cooling solution that replaces the rear door of a server rack, capturing hot exhaust air and transferring heat to a chilled water loop. It eliminates hot spots and supports higher rack power densities.
2.What are the benefits of an RDHX over other liquid cooling solutions?
RDHX units require no additional floor space, integrate directly into standard racks, and enable phased liquid cooling adoption. They eliminate hot air recirculation, reduce reliance on facility air conditioning, and support both new and retrofitted data centers.
3.Is the unit compatible with standard server racks?
EXTRCOOL’s RDHX is designed to fit standard 19-inch server racks and supports standard chilled water pressures and temperatures. Contact our engineering team for tailored compatibility verification with your specific rack and chilled water system.
Product Specification
| Rear Door Heat Exchanger (RDHx) | ||||
| Model Number | EXT-30RDHX | EXT-60RDHX | EXT-90RDHX | EXT-120RDHX |
| Installation Type | Rear door installation (Support top/ bottom water inlet method) | |||
| Rated cooling capacity | 30kW | 60kW | 90kW | 120kW |
| Coolant | PG25 | PG25 | PG25 | PG25 |
| Working environment T&H | -10℃~55℃/ RH5~90% | |||
| Storage environment T&H | -45℃~70℃/RH5~93% | |||
| Air& Liquid temp gap | 15℃/10℃ | 15℃/10℃ | 15℃/10℃ | 15℃/10℃ |
| Air temp.(in/ out) | 42℃/27℃ | 42°C/27℃ | 42°C/27℃ | 42℃/27℃ |
| Secondary side liquid temp.(out/ in) | 24℃/34℃ | 24℃/34℃ | 24℃/34℃ | 24℃/34℃ |
| Air flow rate | 6000m³/h | 12000m³/h | 20000m³/h | 25000m³/h |
| Liquid flow rate | 50LPM | 90LPM | 130LPM | 180LPM |
| Power Supply | 208-277VAC 50/60Hz | |||
| Dual power ATS | Yes | Yes | Yes | Yes |
| Control type | PID control method, regulating fan speed based on temperature sensor (inlet/ outlet air/ supply / return water) |
|||
| Leak Detection | Yes | Yes | Yes | Yes |
| Redundant Fan Automatic Switchover | N+1 | N+1 | N+1 | N+1 |
| Power consumption | <0.7kW | <1.2kW | <2.2kW | <2.6kW |
| Communication | Modbus RTU&TCP/IP | |||
| Design pressure | >10Bar | > 10Bar | >10Bar | >10Bar |
| Approx. Weight | 85kg | 110kg | 155kg | 195kg |
| Protection level | IP55 | IP55 | IP55 | IP55 |
| Dimensions (Wx D x H) mm | 600x210x2000/2200 | 600x210x2000/2200 | 800x240x2200/2200 | 800x240x2200/2200 |