Rack-Mounted Liquid-to-Air CDU for AI & AI Data Centers

4U/6U Rack-Mountable Air-Cooled CDU for High-Density Liquid Cooling Loops

The EXTRCOOL Rack-Mounted Liquid-to-Air (LTA) Cooling Distribution Unit is a compact, standard rack-mounted CDU purpose-built for data center liquid cooling deployments. Designed to pair with NVIDIA GB200/GB300 and high-power GPU servers, this unit integrates liquid-to-air heat exchange, pumping, and intelligent controls into a 4U/6U rack form factor, enabling simplified, space-efficient liquid cooling for new and retrofitted facilities. As rack power densities rise beyond 30kW, this CDU delivers reliable thermal performance without requiring complex chilled water infrastructure.

    Core Technical Advantages

    • Standard Rack-Mount Form Factor Compact 4U/6U design fits directly into standard server racks, eliminating the need for external floor space and simplifying integration with server cold plate loops.
    • Direct Liquid-to-Air Heat Rejection Efficiently dissipates waste heat from liquid cooling loops to ambient air, removing the dependency on chilled water systems and reducing infrastructure costs.
    • Plug-and-Play Integration Pre-configured piping, pumps, and control interfaces enable rapid connection to manifolds and server cold plates, cutting on-site commissioning time.
    • Smart Variable-Speed Operation Dynamic fan and pump adjustment based on coolant temperature minimizes power consumption, lowering data center PUE for sustainable green computing.
    • Enterprise-Grade Reliability Factory pressure-tested components and reinforced seals ensure leak-proof, 24/7 operation for mission-critical data center workloads.

    Product Specifications

    Attribute

    Specification

    Brand

    EXTRCOOL

    Model Series

    CDU-LTA Rack Series

    Cooling Type

    Liquid-to-Air (LTA) Direct Heat Rejection

    Product Category

    Rack-Mounted Cooling Distribution Unit

    Form Factor

    4U / 6U standard rack

    Compatible Systems

    Server cold plate loops, rack-level liquid cooling manifolds

    Place of Origin

    Guangdong, China

    Ideal Application Scenarios

    • Traditional Data Center Retrofit: Low-cost liquid cooling upgrades for existing air-cooled facilities without chilled water infrastructure.
    • Medium-to-High Power Density Racks: Supports 15–30kW rack loads for AI training servers and HPC clusters.
    • Edge & Colocation Data Centers: Compact rack-mount design fits space-constrained deployments.
    • Hybrid Liquid Cooling Architectures: Ideal for phased liquid cooling rollouts, combining air-cooled and liquid-cooled racks.
    • Small-to-Mid-Scale AI Clusters: Simplified, low-maintenance cooling for small-scale GPU deployments.

    Why Choose EXTRCOOL Rack-Mounted LTA CDU?

    The rack-mount form factor eliminates the need for standalone CDU units, offering a space-saving, low-cost solution for transitioning to liquid cooling. EXTRCOOL’s LTA CDU combines high thermal efficiency, simplified installation, and intelligent controls to meet the evolving needs of AI and HPC workloads, ensuring stable, low-noise, and energy-efficient operation year-round.

    Frequently Asked Questions

    1.What is a rack-mounted LTA CDU used for?
    A rack-mounted LTA CDU is a compact, rack-integrated unit that directly rejects waste heat from liquid cooling loops to ambient air, eliminating the need for external heat rejection infrastructure. It is ideal for data centers seeking simplified, space-efficient liquid cooling deployments.

    2.What are the benefits of a rack-mounted vs. standalone CDU?
    The rack-mount design fits directly into server racks, reducing piping complexity and eliminating the need for dedicated floor space. It is fully pre-tested at the factory, minimizing on-site installation errors and ensuring consistent performance from day one.

    3.Is the unit compatible with all server cold plate systems?
    EXTRCOOL’s rack-mounted LTA CDU supports standard liquid loop pressures and temperatures, with customizable flange connections to match most server cold plate and manifold systems. Contact our engineering team for tailored compatibility verification.

    Product Specification

    Product Type Liquid-to-Air Cooling Distribution Unit (L2A CDU)
    Part Number EXT-CDU6AR EXT-CDU15AR EXT-CDU24AR EXT-CDU30AR
    Installation Type In Rack
    Rated cooling capacity 6kW 15kW 24kW 30kW
    Coolant PG25 PG25 PG25 PG25
    Working environmentT&H -10℃~55℃/ RH5~90%
    Storage environmentT&H -45℃~70℃/RH5~93%
    Inch display screen 4.3" 4.3" 7" 7"
    Approach temperature 10℃ 10℃ 10℃ 10℃
    Primary side air or liquid temp.(in/ out) 25℃/35℃
    Secondary side liquid temp.(out/ in) 35℃/45℃ 35℃/45℃ 35℃/45℃ 35℃/45℃
    Secondary side rated flow rate 10LPM 25LPM 40LPM 50LPM
    Power Supply AC220V 50/60Hz
    Dual power ATS Yes Yes Yes Yes
    Leak Detection Yes Yes Yes Yes
    Redundant Pump Automatic Switchover 1+1 1+1 1+1 1+1
    Power consumption <0.3kW <1kW <1.5kW <3kW
    Bypass Online Replaceable Filter No No No No
    Control type PID control method, Adju st air volume and flow rate according to temperature
    Communication Modbus RTU&TCP/IP
    Approx. Weight 40kg 75kg 105kg 135kg
    Protection level IP55 IP55 IP55 IP55
    Dimensions(Wx D x H) mm 482x870x177.8 482x870x443 482x870x665 482x870x887