The CDU, short for Coolant Distribution Unit, is the control hub between the primary cold source and the secondary IT equipment, and it does four things: the plate heat exchanger moves GPU and CPU heat to the chilled water while keeping the loops hydraulically isolated; variable frequency pumps drive the closed loop and spread coolant evenly to every rack and cold plate; sensors adjust pump speed and valve opening to hold temperature within ±0.5°C and pressure within ±0.1bar above the dew point; leak detection, filtration and auto refill protect the loop at 0.01 to 0.1 mL/min resolution with N+1 redundancy. The AI server air liquid cooling CDU is the air-to-liquid member of this architecture; the heart pumps, the brain regulates.

view detail
The Manifold, the Blood Vessel Trunk That Feeds Every Server

The Manifold, the Blood Vessel Trunk That Feeds Every Server

2026-09-30

The manifold, also called the distribution header or collector, is the core component of a cold plate liquid cooling system responsible for coolant distribution and return, mounted at the rack rear between the CDU and the server cold plates. The CDU is the heart, handling total flow, temperature and pressure; the manifold is the blood vessel trunk inside the rack, splitting coolant evenly to every layer of server cold plates, gathering it after heat absorption and sending it back to the CDU to complete the closed loop. That is the part a cold plate liquid manifold supplier engineers first.

view detail
The Manifold, the Water Pipe That Only Eight Companies Can Make

The Manifold, the Water Pipe That Only Eight Companies Can Make

2026-09-30

The manifold, also called the splitter or distributor, is the fluid distribution hub between the CDU and the server cold plates; it splits coolant to every node, collects the return, holds pressure and guards flow balance, and one uneven branch means a rack of GPUs running hot. It comes in two levels with a tenfold price gap: the inner manifold in the server tray at about $1,000, the rack manifold at about $10,000. Single-row designs serve 10 to 30kW racks with up to 12 interfaces; double-row designs serve 50 to 120kW AI racks with 16 or more and branch deviation within 5%; typical specs run 2 to 4mm wall, 8 to 24 branches, 10 bar or more. The liquid distribution manifold serves AI servers, HPC, telecom, energy storage and battery thermal management alike.

view detail
Cooling the AI Boom, Liquid Cooling Routes and the Vendors Racing In

Cooling the AI Boom, Liquid Cooling Routes and the Vendors Racing In

2026-09-30

AI compute is surging and thermal power is the urgent problem, not only in AI data centers, since most 3C products depend on thermal modules. Liquid cooling divides into liquid-to-air and liquid-to-liquid: GB200 NVL72 on the 1U chassis takes the liquid-to-liquid route, while NVL36 on the 2U chassis lets most cloud providers deploy liquid cooling in existing data centers. Penetration takes off in 2025, and high unit value makes it the main sales driver for the AI GPU liquid cooling CDU manufacturer base.

view detail
The Hidden Bottleneck, Why Liquid Cooling Piping Must Leave the Site

The Hidden Bottleneck, Why Liquid Cooling Piping Must Leave the Site

2026-09-30

Liquid cooling projects moving from demonstration pilots of dozens of racks to large-scale cluster delivery of hundreds or thousands are forming a shared conclusion: the core that constrains delivery efficiency and decides long-term reliability is not the CDU or the cold plate but the secondary-side piping spread across the machine room. Small projects deliver through on-site measurement, cutting, welding and cleaning; once a single project scales and multiple projects run in parallel, that model breaks, and piping is moving from site fabrication to factory prefabrication, a restructuring of the underlying logic that already governs the server liquid cooling piping manifold.

view detail
EXTRCOOL Inverter Cold Room, Fast-Install Cold Storage Built on Standardized Manufacturing

EXTRCOOL Inverter Cold Room, Fast-Install Cold Storage Built on Standardized Manufacturing

2026-09-30

Store openings and new product launches run on a short selling window, while a conventional cold room takes ten days to half a month for installation and debugging and the peak season passes in that time. Cold rooms stayed a slow craft: non-standard assembly, on-site welding, repeated commissioning, and a unit that finally runs after the season only breaks even. A fruit and vegetable merchant needs a fruit vegetable cold room refrigeration unit that goes live within days to catch the window at all. EXTRCOOL Inverter Cold Room addresses this directly with standardized complete-set design, moving installation from slow craft to fast install and fast use.

view detail
EXTRCOOL Inverter Cold Room Unit, Fast Cooling That Locks Freshness at the Door

EXTRCOOL Inverter Cold Room Unit, Fast Cooling That Locks Freshness at the Door

2026-09-30

Cold room operators' biggest fear is goods arriving while the temperature has not dropped yet. During the early-morning stocking peak, trucks of fresh produce, meat and prepared dishes queue for the room, the door opens and closes repeatedly and every open door pushes the room temperature up in a thermal shock; when the cold room refrigeration unit cannot recover fast enough, the goods wait at room temperature and each extra minute costs a measure of quality. Slow pull-down is a loss problem and a profit problem, not an efficiency problem.

view detail
EXTRCOOL Inverter Cold Room, Three Layers of Design for Quiet Operation

EXTRCOOL Inverter Cold Room, Three Layers of Design for Quiet Operation

2026-09-30

EXTRCOOL Inverter Cold Room uses a specially designed double-sided felt sandwich sound-absorbing cotton that delivers more than five times the sound absorption and insulation of ordinary material, and with internal and external dual-silent design the overall operating noise stays between 38 and 66 dB(A) depending on model, so the room cools at full efficiency while the surrounding space stays quiet. That is the standard a low noise cold room refrigeration unit is judged by.

view detail
EXTRCOOL Deep Freeze Cold Room, Keeping Freshness Locked at the Cell Level

EXTRCOOL Deep Freeze Cold Room, Keeping Freshness Locked at the Cell Level

2026-09-30

The EXTRCOOL Inverter Cold Room deep-freeze system reaches a stable -40°C room temperature through patented single-unit cascade dual-stage scroll compression, and AI inverter precise temperature control locks freshness at the cell level, so thawed ingredients release little blood water, keep their color and taste as fresh as the original, breaking the industry bottleneck where ordinary cold rooms freeze too slowly and lose too much nutrition. The low temperature cold room refrigeration unit is judged by the temperature it can hold and the cell structure it preserves.

view detail
EXTRCOOL Inverter Cold Room, Long-Lasting, Energy-Saving and Fully Supported

EXTRCOOL Inverter Cold Room, Long-Lasting, Energy-Saving and Fully Supported

2026-09-30

Fresh retail, catering cold chain and agricultural planting merchants face the same set of operating problems: sheet metal rusts and cold leaks shortly after installation, electricity bills stay high, room temperature swings during defrost and goods are lost, and slow repairs disrupt normal business. EXTRCOOL Inverter Cold Room, built on the parent company's decades of refrigeration technology, addresses the three dimensions of material selection, intelligent performance and compliant after-sales to deliver stable, energy-saving, durable commercial cold rooms, and the low power consumption cold room refrigeration unit is the answer to the highest line on the monthly bill.

view detail

Leave Your Message

Your Name*

Phone Number

Company

Remarks*

reset